<ErrorNumber>22287</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Unable to calibrate Picker vacuum threshold
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This may occur duiring the monitor command 'cal picker'.
Check that there are plates with slipsheets between in the
current bay (cassette). There should be no slipsheet on top of
the first plate.
</text></DescriptionText>
<DescriptionText><text>
The sst may be set manually.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Not applicable
</text></DescriptionText>
</OperatorAction>
<Cause>
Subsequent readings of the same point on the plate or slipsheet,
differ by too much (10).  Could be caused by fluctuating air pressure,
a bad vacuum generator or dirt in the vacuum system, or by a bad sensor
or Genine board.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/cal_picker.xml</LinkAddress><LinkTitle>Command: cal picker</LinkTitle></Link>
<Link><LinkAddress>../commands/cal_pvth.xml</LinkAddress><LinkTitle>Command: cal pvth</LinkTitle></Link>
<Link><LinkAddress>../nvs/val_cfg_pvth.xml</LinkAddress><LinkTitle>NVS: val pvth</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:03 2008 PST
</Updated>
<Links>
</Links>
</Error>